• GCS180 Series

    Features

    • Single outputs from 12V to 48VDC
    • Universal 85 to 264VAC input range
    • ITE and medical safety approvals (Class I & II)
    • <0.5W standby power
    • Class B emissions
    • Remote on/off optional, 12VDC 0.6A fan supply
    • Overcurrent, overvoltage and short-circuit protection
    • Operating temperature range from -40°C to +70°C
    • 3 year warranty
    GCS180 Series, 180 Watts, Open PCB or Enclosed, 5 Models 12V to 48V DC Outputs. Class I & II installations. Medical & ITE Safety Approvals.

    Inquiry Info. PDF

  • GCS250 Series

    Features

    • Single outputs from 12V to 56VDC
    • Universal 85 to 264VAC input range
    • High efficiency – up to 93%
    • ITE and medical safety approvals (Class I & II)
    • 4kVAC input to output isolation
    • Class B conducted emissions
    • Remote on/off option, 12VDC 0.6A fan supply
    • Overcurrent, overvoltage and short-circuit protection
    • Operating temperature range from -40°C to +70°C
    GCS250 Series, 250 Watts, Open PCB or Enclosed, 6 Models 12V to 56V DC Outputs. Class I & II installations. Medical & ITE Safety Approvals.

    Inquiry Info. PDF

  • GCS265 Series

    Features

    • Single outputs from 12V to 48VDC
    • Universal 85 to 264VAC input range
    • High efficiency – up to 93%
    • ITE and medical safety approvals (Class I & II)
    • 4kVAC input to output isolation
    • Class B conducted emissions
    • 5V/3A Standby Output
    • Remote on/off option, remote sense and DC OK signal
    • Overcurrent, overvoltage and short-circuit protection
    • Operating temperature range from -40°C to +70°C
    GCS265 Series, 265 Watts, Open PCB or Enclosed, 5 Models 12V to 48V DC Outputs. Class I & II installations. Medical & ITE Safety Approvals.

    Inquiry Info. PDF

  • GCS350 Series

    Features

    • Single outputs from 12V to 56VDC
    • Universal 85 to 264VAC input range
    • High efficiency – up to 93%
    • ITE and medical safety approvals (Class I & II)
    • 4kVAC input to output isolation
    • Class B conducted emissions
    • Remote On/Off, 12VDC 0.6A fan supply
    • Overcurrent, overvoltage and short-circuit
    • protection
    • -40°C to +70°C operating temperature
    • 3 year warranty
    GCS350 Series, 350 Watts, Open PCB or Enclosed, 6 Models 12V to 56V DC Outputs. Class I & II installations. Medical & ITE Safety Approvals.

    Inquiry Info. PDF

  • MBU250 Series

    Features

    • Wide Operating Voltage, 90 to 264 VAC, 47 to 63 Hz
    • Single Output
    • Protection: OVP, OLP, OTP
    • Size: 3″x 5″x 1.46″
    • Input to Output: 2MOPP
    • High ESD Immunity
    • Suitable Professional Healthcare Facility
    • 5-Year Warranty
    MBU250 Series, 250 Watts, Open PCB, 7 Models 12V to 48V DC Outputs. Class I installations. Medical Safety Approvals.

    Inquiry Info. PDF

  • MBU500 Series

    Features

    • Wide Operating Voltage, 90 to 264 VAC, 47 to 63 Hz
    • Single Output
    • Protection: OVP, OLP, OTP, OCP
    • Size : 3″x 5″x 1.38″
    • Input to Output : 2MOPP
    • High Power Density
    • Suitable Professional Healthcare Facility
    • 5-Year Warranty
    MBU500 Series, 250 Watts, Open PCB, 7 Models 12V to 48V DC Outputs. Class I installations. Medical Safety Approvals.

    Inquiry Info. PDF

  • JB400D Series

    Features

    • Safety Approvals to IEC/EN/UL60601-1 3rd Edition
    • High Quality & Reliable Component Usage
    • Variable Fan Speed & Low Acoustical Noise
    • 5/ 12/ 24V Dual Output Optional Combinations
    • U-Chassis Type drive max 250W under air convection
    • Active Power Factor Corrected to EN61000-3-2 class D
    • U-Chassis & Enclosed with built-in fan Mechanical Options
    JB400D, 400 Watts, U Channel or Enclosed, Dual outputs, 3 Models 5V & 12V, 5V & 24V or 12V & 24V DC Class I installations. Medical & ITE Safety Approvals.

    Inquiry Info. PDF

  • ECH450 Series

    Features

    • Force cooled and convection cooled ratings
    • Medical and ITE approvals
    • Compact 3.0″ by 5.0″ footprint
    • Suitable for BF applications
    • 5 V standby and remote on/off
    • 12 V fan output
    • -20 °C to +70 °C operation
    • High efficiency, up to 94%
    ECH450 Series, 450 Watts, Open PCB or Enclosed 7 Models 12V to 54V DC Outputs. Class I & II installations. Medical & ITE Safety Approvals.

    Inquiry Info. PDF

  • CCR420 Series

    Features

    • 420W fan cooled, 350W conduction cooled
    • Universal, single phase input: 85 to 264VAC
    • 129.4 x 83.5mm footprint, 25.4mm profile
    • High efficiency, up to 94%
    • Low earth leakage <300µA
    • Low patient leakage <75µA
    • Medical (BF) & ITE safety approvals
    • Class B conducted and radiated emissions
    • 3 year warranty
    CCR420 Series, 420 Watts, Enclosed, Ultra compact, 8 models from 12V to 54V DC Outputs. Medical & ITE Safety Approvals.

    Inquiry Info. PDF

  • CCR550 Series

    Features

    • 550W fan cooled, 450W conduction cooled
    • Universal, single phase input: 85 to 264VAC
    • 129.4 x 83.5mm footprint, 25.4mm profile
    • High efficiency, up to 94%
    • Low earth leakage <300µA
    • Low patient leakage <90µA
    • Medical (BF) & ITE safety approvals
    • Class B conducted and radiated emissions
    • 3 year warranty
    CCR550 Series, 550 Watts, Enclosed, Ultra compact, 8 models from 12V to 54V DC Outputs. Medical & ITE Safety Approvals.

    Inquiry Info. PDF

Total of 47 results