• JCM30 Series

    Features

    • Regulated single outputs from 3.3 to 15VDC
    • Regulated dual outputs ±12 & ±15VDC
    • 2:1 input range
    • Input ranges 9 to 18, 16 to 36, 36 to 75VDC
    • 25.4 x 25.4mm (1» x 1») package, 10.4mm profile
    • 1.6kVDC isolation
    • Remote On/Off
    • -40°C to +100°C operating temperature
    • Full power to +55°C
    • 3 year warranty
    JCM30 Series 30 Watts, 25.4 x 25.4 metal package, 2:1, 12V, 24V or 48V DC Input, Single and dual regulated output versions from 3.3V to 15V DC, 1.6kVDC isolation, Single outputs ±10% trim adjustable, Remote On/Off

    Inquiry Info. PDF

  • JTM20

    Features

    • Wide 4:1 Input Range
    • Single & Dual Outputs
    • -40 °C to +105 °C Operating Temperature
    • Overvoltage & Overcurrent Protection
    • Remote On/Off
    • 1600 VDC Isolation
    • 3 Year Warranty
    JTM20 Series 20 Watts, 50.8 x 25.4 metal package, 4:1 24V or 48V DC Input, Single and dual regulated output versions from 3.3V to 15V DC, 1.6kVDC isolation, Single outputs ±10% trim adjustable, Remote On/Off

    Inquiry Info. PDF

  • RDF25

    Features

    • Single voltage outputs from 5V to 24VDC
    • Wide output voltage trim and remote sense
    • 10:1 ultra-wide input range 16 to 160VDC
    • Industry standard half brick format
    • High efficiency, up to 85%
    • 3kVAC reinforced input to output isolation
    • ITE safety approvals and EN50155 compliance
    • Remote On/Off with low 15mA stand-by current
    • -40°C to +100°C operating temperature
    • Overvoltage, overload, and short circuit protection
    • 3 year warranty
    RDF25 Series 25W, 50.8 x 25.4 metal package, 10:1 16V-160V DC Input, Single regulated outputs of 5V, 12V, 15V or 24V DC. 3kVAC reinforced isolation, Outputs ±10% trim adjustable, Remote On/Off

    Inquiry Info. PDF

  • JTK15

    Features

    • Regulated single outputs 3.3 to 15VDC
    • Regulated dual outputs ±5, ±12 & ±15VDC
    • 4:1 input range
    • 25.4 x 25.4mm (1” x 1”) footprint, 9.9mm profile
    • Output trim ±10% (single O/P)
    • 1.6kVDC isolation
    • Remote On/Off
    • -40°C to +100°C operating temperature
    • Full power to +65°C
    • 3 year warranty
    JTK15 Series 15 Watts, 25.4 x 25.4 metal package, 4:1 24V or 48V DC Input, Single and dual regulated output versions from 3.3V to 15V DC, 1.6kVDC isolation, Single outputs ±10% trim adjustable, Remote On/Off

    Inquiry Info. PDF

  • JTK20

    Features

    • Regulated single outputs 3.3 to 15VDC
    • Regulated dual outputs ±12 & ±15VDC
    • 4:1 input range
    • 25.4 x 25.4mm (1” x 1”) footprint, 9.9mm profile
    • Output trim ±10% (single O/P)
    • 1.6kVDC isolation
    • Remote On/Off
    • -40°C to +100°C operating temperature
    • Full power to +55°C
    • 3 year warranty
    JTK20 Series 20 Watts, 25.4 x 25.4 metal package, 4:1 24V or 48V DC Input, Single and dual regulated output versions from 3.3V to 15V DC, 1.6kVDC isolation, Single outputs ±10% trim adjustable, Remote On/Off

    Inquiry Info. PDF

  • JTK30 Series

    Features

    • Regulated single outputs 3.3 to 15VDC
    • Regulated dual outputs ±12 & ±15VDC
    • 4:1 input range
    • 25.4 x 25.4mm (1” x 1”) footprint, 10.9mm (0.46”) profile
    • Output trim ±10% (single O/P)
    • 1.6kVDC isolation
    • Remote On/Off
    • Optional heatsink
    • -40°C to +100°C operating temperature
    • Full power to +55°C
    • 3 year warranty
    JTK30 Series 30 Watts, 25.4 x 25.4 metal package, 4:1 24V or 48V DC Input, Single and dual regulated output versions from 3.3V to 15V DC, 1.6kVDC isolation, Single outputs ±10% trim adjustable, Remote On/Off

    Inquiry Info. PDF

  • JCK15 Series

    Features

    • Regulated single outputs 3.3, 5, 12 & 15VDC
    • Regulated dual outputs ±3.3, ±5, ±12 & ±15VDC
    • 2:1 input range
    • 50.8 x 25.4mm (2” x 1”) footprint, 10.2mm profile
    • 1.6kVDC isolation
    • Continuous short circuit protection
    • Optional heatsink
    • -40°C to +100°C operating temperature
    • Full power to +70°C
    • 3 year warranty
    JCK15 Series 15 Watts, 50.8 x 25.4 metal package, 2:1, 12V, 24V or 48V DC Input, Single and dual regulated output versions from 3.3V to 15V DC, 1.6kVDC isolation, Single outputs ±10% trim adjustable

    Inquiry Info. PDF

  • JCK20 Series

    Features

    • Regulated single outputs 3.3, 5, 12 & 15VDC
    • Regulated dual outputs ±12 & ±15VDC
    • 2:1 input range
    • 50.8 x 25.4mm (2” x 1”) footprint, 10.2mm profile
    • 1.6kVDC isolation
    • Single outputs trimmable ±10%
    • Remote On/Off
    • Continuous short circuit protection
    • Optional heatsink
    • -40°C to +100°C operating temperature
    • Full power to +70°C
    • 3 year warranty
    JCK20 Series 20 Watts, 50.8 x 25.4 metal package, 2:1, 12V, 24V or 48V DC Input, Single and dual regulated output versions from 3.3V to 15V DC, 1.6kVDC isolation, Single outputs ±10% trim adjustable, Remote On/Off

    Inquiry Info. PDF

  • JCK30 Series

    Features

    • Regulated single outputs 3.3, 5, 12 & 15VDC
    • Regulated dual outputs ±12 & ±15VDC
    • 2:1 input range
    • 50.8 x 25.4mm (2” x 1”) footprint, 0.4’’ profile
    • 1.6kVDC isolation
    • Single outputs trimmable ±10%
    • Remote On/Off
    • Continuous short circuit protection
    • Optional heatsink
    • -40°C to +75°C operating temperature
    • Full power to +50°C
    • 3 year warrant
    JCK30 Series 30 Watts, 50.8 x 25.4 metal package, 2:1, 12V, 24V or 48V DC Input, Single and dual regulated output versions from 3.3V to 15V DC, 1.6kVDC isolation, Single outputs ±10% trim adjustable, Remote On/Off

    Inquiry Info. PDF

  • JCK40 Series

    Features

    • Regulated single outputs 3.3, 5, 12 & 15VDC
    • Regulated dual outputs ±12 & ±15VDC
    • 2:1 input range
    • 50.8 x 25.4mm (2” x 1”) footprint, 10.2mm profile
    • 1.6kVDC isolation
    • Single outputs trimmable ±10%
    • Remote On/Off
    • Continuous short circuit protection
    • Optional heatsink
    • -40°C to +105°C operating temperature
    • Full power to +40°C
    • 3 year warranty
    JCK40 Series 40 Watts, 50.8 x 25.4 metal package, 2:1, 12V, 24V or 48V DC Input, Single and dual regulated output versions from 3.3V to 15V DC, 1.6kVDC isolation, Single outputs ±10% trim adjustable, Remote On/Off

    Inquiry Info. PDF

Total of 123 results